The TMP1101 allows you to measure extreme temperatures with up to 4 thermocouples. It is great for measuring temperatures in enclosed spaces or in liquids. This Phidget connects to your computer through a VINT Hub.
Board | |
---|---|
Controlled By | VINT |
Number of Thermocouple Inputs | 4 |
Thermocouple Input | |
Thermocouple Error Max (K-Type) | ± 2 °C |
Thermocouple Temperature Resolution (K-Type) | 0.04 °C |
Sampling Interval Min | 20 ms/sample |
Sampling Interval Max | 60 s/sample |
Thermocouple Voltage Resolution | 1 μV DC |
Onboard Temperature Sensor | |
Temperature Error Max | ± 1 °C |
Sampling Interval Max | 60 s/sample |
Sampling Interval Min | 500 ms/sample |
Temperature Error Typical (At 25°C) | ± 0.25 °C |
Temperature Resolution | 0.063 °C |
Temperature Max | 85 °C |
Temperature Min | -40 °C |
Electrical Properties | |
Current Consumption Min | 10 μA |
Current Consumption Max | 7 mA |
Physical Properties | |
Recommended Wire Size | 16 - 26 AWG |
Operating Temperature Min | -40 °C |
Operating Temperature Max | 85 °C |
Customs Information | |
Canadian HS Export Code | 8471.80.00 |
American HTS Import Code | 8471.80.40.00 |
Country of Origin | CN (China) |